Abstract
Objectives
To determine reference values for the 1-min sit-to-stand (STS) test in an adult population.
Methods
Cross-sectional study nested within a nationwide health promotion campaign in Switzerland. Adults performed the STS test and completed questions on demographics and health behavior.
Results
6,926 out of 7,753 (89.3 %) adults were able to complete the STS test. The median number of repetitions ranged from 50/min (25–75th percentile 41–57/min) in young men and 47/min (39–55/min) in young women aged 20–24 years to 30/min (25–37/min) in older men and 27/min (22–30/min) in older women aged 75–79 years.
Conclusions
The reference values support the interpretation of 1-min STS test performance and identification of subjects with decreased lower body muscular strength and endurance.
References
Bautmans I, Lambert M, Mets T (2004) The six-minute walk test in community dwelling elderly: influence of health status. BMC Geriatr 4:1–9
Bohannon RW (1995) Sit-to-stand test for measuring performance of lower extremity muscles. Percept Mot Skills 80:163–166
Bohannon RW (2006) Reference values for the five-repetition sit-to-stand test: a descriptive meta-analysis of data from elders. Percept Mot Skills 103:215–222
Bohannon RW (2012) Measurement of sit-to-stand among older adults. Topics Geriartic Rehabil 28:11–16
Cohen P (1992) A power primer. Psychol Bull 112:155–159
Janssen WGM, Bussmann HBJ, Stam HJ (2002) Determinants of the sit-to-stand movement: a review. Phys Ther 82:866–879
Jones CJ, Rikli RE, Beam WC (1999) A 30-s chair-stand test as a measure of lower body strength in community-residing older adults. Res Q Exerc Sport 70:113–119
Kasymjanova G, Correa JA, Kreisman H, Dajczman E, Pepe C, Dobson S, Lajeunesse L, Sharma R, Small D (2009) Prognostic value of the six-minute walk in advanced non-small cell lung cancer. J Thorac Oncol 4:602–607
Lord SR, Murray SM, Chapman K, Munro B, Tiedemann A (2002) Sit-to-stand performance depends on sensation, speed, balance, and psychological status in addition to strength in older people. J Gerontol A Biol Sci Med Sci 57:M539–M543
Myers J, Prakash M, Froelicher V, Do D, Partington S, Atwood JE (2002) Exercise capacity and mortality among men referred for exercise testing. N Engl J Med 346:793–801
Ozalevli S, Ozden A, Itil O, Akkoclu A (2007) Comparison of the sit-to-stand test with 6 min walk test in patients with chronic obstructive pulmonary disease. Respir Med 101:286–293
Pinto-Plata VM, Cote C, Cabral H, Taylor J, Celli BR (2004) The 6-min walk distance: change over time and value as a predictor of survival in severe COPD. Eur Respir J 23:28–33
Puhan M, Siebling L, Zoller M, Muggensturm P, ter Riet G (2013) Simple functional performance tests and mortality in COPD. Eur Resp J, pp 1–22. doi:10.1183/09031936.00131612
Rikli RE, Jones CJ (1999) Functional fitness normative scores for community-residing older adults, ages 60–94. J Aging Phys Act 7:162–181
Ritchie C, Trost SG, Brown W, Armit C (2005) Reliability and validity of physical fitness field tests for adults aged 55 to 70 years. J Sci Med Sports 8:61–70
Roger VL, Jacobsen SJ, Pellikka PA, Miller TD, Bailey KR, Gersh BJ (1998) Prognostic value of treadmill exercise testing. Circulation 98:2836–2841
Solberg HE (2004) The IFCC recommendation on estimation of reference intervals. The RefVal program. Clin Chem Lab Med 42:710–714
Wright EM, Royston P (1999) Calculating reference intervals for laboratory measurements. Stat Methods Med Res 8:93–112
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Strassmann, A., Steurer-Stey, C., Lana, K.D. et al. Population-based reference values for the 1-min sit-to-stand test. Int J Public Health 58, 949–953 (2013). https://doi.org/10.1007/s00038-013-0504-z
Received:
Revised:
Accepted:
Published:
Issue date:
DOI: https://doi.org/10.1007/s00038-013-0504-z