Info
Artikel von Michael George
Aktivitäten
20.373 Follower:innen
Berufserfahrung und Ausbildung
Veröffentlichungen
-
Automated Patch Clamp Meets High-Throughput Screening: 384 Cells Recorded in Parallel on a Planar Patch Clamp Module
Journal of Laboratory Automation
We have developed an automated patch clamp module for high-throughput ion channel screening, recording from 384 cells simultaneously. The module is incorporated into a laboratory pipetting robot and uses a 384-channel pipettor head for application of cells and compounds. The module contains 384 amplifier channels for fully parallel recordings using a digital amplifier. Success rates for completed experiments (1- to 4-point concentration–response curves for cells satisfying defined quality…
We have developed an automated patch clamp module for high-throughput ion channel screening, recording from 384 cells simultaneously. The module is incorporated into a laboratory pipetting robot and uses a 384-channel pipettor head for application of cells and compounds. The module contains 384 amplifier channels for fully parallel recordings using a digital amplifier. Success rates for completed experiments (1- to 4-point concentration–response curves for cells satisfying defined quality control parameters) of greater than 85% have been routinely achieved with, for example, HEK, CHO, and RBL cell lines expressing hNaV1.7, hERG, Kir2.1, GABA, or glutamate receptors. Pharmacology experiments are recorded and analyzed using specialized software, and the pharmacology of hNaV1.7 and hERG is described. Fast external solution exchange rates of <50 ms are demonstrated using Kir2.1. Short exposure times are achieved by stacking the external solutions inside the pipette of the robot to minimize exposure of the ligand on the receptor. This ensures that ligand-gated ion channels, for example, GABA and glutamate described in this report, can be reproducibly recorded. Stem cell–derived cardiomyocytes have also been used with success rates of 52% for cells that have a seal resistance of >200 MΩ, and recordings of voltage-gated Na+ and Ca2+ are shown.
Andere Autor:innenVeröffentlichung anzeigen -
Automated Patch Clamp Analysis of nAChα7 and NaV1.7 Channels
Current Protocols in Pharmacology
Automated patch clamp devices are now commonly used for studying ion channels. A useful modification of this approach is the replacement of the glass pipet with a thin planar glass layer with a small hole in the middle. Planar patch clamp devices, such as the three described in this unit, are overtaking glass pipets in popularity because they increase throughput, are easier to use, provide for the acquisition of high‐quality and information‐rich data, and allow for rapid perfusion and…
Automated patch clamp devices are now commonly used for studying ion channels. A useful modification of this approach is the replacement of the glass pipet with a thin planar glass layer with a small hole in the middle. Planar patch clamp devices, such as the three described in this unit, are overtaking glass pipets in popularity because they increase throughput, are easier to use, provide for the acquisition of high‐quality and information‐rich data, and allow for rapid perfusion and temperature control. Covered in this unit are two challenging targets in drug discovery: voltage‐gated sodium subtype 1.7 (NaV1.7) and nicotinic acetylcholine α7 receptors (nAChα7R). Provided herein are protocols for recording activation and inactivation kinetics of NaV1.7, and activation and allosteric modulation of nAChα7R. Curr. Protoc. Pharmacol. 65:11.13.1‐11.13.48. © 2014 by John Wiley & Sons, Inc.
Keywords: automated patch clamp; NaV1.7; nicotinic acetylcholine receptorsAndere Autor:innenVeröffentlichung anzeigen -
Minimized cell usage for stem cell-derived and primary cells on an automated patch clamp system
Journal of Pharmacological and Toxicological Methods
Chip-based automated patch clamp systems are widely used in drug development and safety pharmacology, allowing for high quality, high throughput screening at standardized experimental conditions.
The merits of automation generally come at the cost of large amounts of cells needed, since cells are not targeted individually, but randomly positioned onto the chip aperture from cells in suspension. While cell usage is of little concern when using standard cell lines such as CHO or HEK cells, it…Chip-based automated patch clamp systems are widely used in drug development and safety pharmacology, allowing for high quality, high throughput screening at standardized experimental conditions.
The merits of automation generally come at the cost of large amounts of cells needed, since cells are not targeted individually, but randomly positioned onto the chip aperture from cells in suspension. While cell usage is of little concern when using standard cell lines such as CHO or HEK cells, it becomes a crucial constraint with cells of limited availability, such as primary or otherwise rare and expensive cells, like induced pluripotent stem (IPS) cell-derived cardiomyocytes or neurons.
Methods: We established application protocols for CHO cells, IPS cell-derived neurons (iCell® Neurons, Cellular Dynamics International), cardiomyocytes (Cor.4U®, Axiogenesis) and pancreatic islet cells, minimizing cell usage for automated patch clamp recordings on Nanion's Patchliner. Use of 5 μl cell suspension per well for densities between 55,000 cells/ml and 400,000 cells/ml depending on cell type resulted in good cell capture.
Results:We present a new cell application procedure optimized for the Patchliner achieving > 80% success rates for using as little as 300 to 2000 cells per well depending on cell type.We demonstrate that this protocol works for standard cell lines, as well as for stem cell-derived neurons and cardiomyocytes, and for primary pancreatic islet cells. We present recordings for these cell types, demonstrating that high data quality is not compromised by altered cell application.
Discussion: Our new cell application procedure achieves high success rates with unprecedentedly low cell numbers.
Compared to other standard automated patch clamp systems we reduced the average amount of cells needed bymore than 150 times. Reduced cell usage crucially improves cost efficiency for expensive cells and opens up automated patch clamp for primary cells of limited availability.
Andere Autor:innenVeröffentlichung anzeigen -
Characterizing Human Ion Channels in Induced Pluripotent Stem Cell-Derived Neurons
Journal of Biomolecular Screening
Neurons derived from human-induced pluripotent stem cells were characterized using manual and automated patch-clamp recordings. These cells expressed voltage-gated Na+ (Nav), Ca2+ (Cav), and K+ (Kv) channels as expected from excitable cells. The Nav current was TTX sensitive, IC50 = 12 ± 6 nM (n = 5). About 50% of the Cav current was blocked by 10 µM of the L-type channel blocker nifedipine. Two populations of the Kv channel were present in different proportions: an inactivating (A-type) and a…
Neurons derived from human-induced pluripotent stem cells were characterized using manual and automated patch-clamp recordings. These cells expressed voltage-gated Na+ (Nav), Ca2+ (Cav), and K+ (Kv) channels as expected from excitable cells. The Nav current was TTX sensitive, IC50 = 12 ± 6 nM (n = 5). About 50% of the Cav current was blocked by 10 µM of the L-type channel blocker nifedipine. Two populations of the Kv channel were present in different proportions: an inactivating (A-type) and a noninactivating type. The A-type current was sensitive to 4-AP and TEA (IC50 = 163 ± 93 µM; n = 3). Application of γ-aminobutyric acid (GABA) activated a current sensitive to the GABAA receptor antagonist bicuculline, IC50 = 632 ± 149 nM (n = 5). In both devices, comparable action potentials were generated in the current clamp. With unbiased, automated patch clamp, about 40% of the cells expressed Nav currents, whereas visual guidance in manual patch clamp provided almost a 100% success rate of patching “excitable cells.” These results show high potential for pluripotent stem cell–derived neurons as a useful model for drug discovery, in combination with automated patch-clamp recordings for high-throughput and high-quality drug assessments at human neuronal ion channels in their correct cellular background.
Andere Autor:innenVeröffentlichung anzeigen -
State-of-the-art automated patchclamp devices: heatactivation, actionpotentials, and highthroughput in ionchannel screening
Frontiers in Pharmacology
Ion channels are essential in a wide range of cellular functions and their malfunction underlies many disease states making them important targets in drug discovery. The availability of standardized cell lines expressing ion channels of interest lead to the development of diverse automated patch clamp (APC) systems with high-throughput capabilities. These systems are now available for drug screening, but there are limitations in the application range. However, further development of existing…
Ion channels are essential in a wide range of cellular functions and their malfunction underlies many disease states making them important targets in drug discovery. The availability of standardized cell lines expressing ion channels of interest lead to the development of diverse automated patch clamp (APC) systems with high-throughput capabilities. These systems are now available for drug screening, but there are limitations in the application range. However, further development of existing devices and introduction of new systems widen the range of possible experiments and increase throughput. The addition of well controlled and fast solution exchange, temperature control and the availability of the current clamp mode are required to analyze standard cell lines and excitable cells such as stem cell-derived cardiomyocytes in a more physiologically relevant environment. Here we describe two systems with different areas of applications that meet the needs of drug discovery researchers and basic researchers alike. The here utilized medium throughput APC device is a planar patch clamp system capable of recording up to eight cells simultaneously. Features such as temperature control and recordings in the current clamp mode are described here. Standard cell lines and excitable cells such as stem cell-derived cardiomyocytes have been used in the voltage clamp and current clamp modes with the view to finding new drug candidates and safety testing methods in a more physiologically relevant environment. The high-throughput system used here is a planar patch clamp screening platform capable of recording from 96 cells in parallel and offers a throughput of 5000 data points per day. Full dose response curves can be acquired from individual cells reducing the cost per data point. The data provided reveals the suitability and relevance of both APC platforms for drug discovery, ion channel research, and safety testing.
Andere Autor:innenVeröffentlichung anzeigen -
Automated Patch Clamp on mESC-Derived Cardiomyocytes for Cardiotoxicity Prediction
Journal of Biomolecular Screening
Cardiovascular side effects are critical in drug development and have frequently led to late-stage project terminations or even drug withdrawal from the market. Physiologically relevant and predictive assays for cardiotoxicity are hence strongly demanded by the pharmaceutical industry. To identify a potential impact of test compounds on ventricular repolarization, typically a variety of ion channels in diverse heterologously expressing cells have to be investigated. Similar to primary cells, in…
Cardiovascular side effects are critical in drug development and have frequently led to late-stage project terminations or even drug withdrawal from the market. Physiologically relevant and predictive assays for cardiotoxicity are hence strongly demanded by the pharmaceutical industry. To identify a potential impact of test compounds on ventricular repolarization, typically a variety of ion channels in diverse heterologously expressing cells have to be investigated. Similar to primary cells, in vitro–generated stem cell–derived cardiomyocytes simultaneously express cardiac ion channels. Thus, they more accurately represent the native situation compared with cell lines overexpressing only a single type of ion channel. The aim of this study was to determine if stem cell–derived cardiomyocytes are suited for use in an automated patch clamp system. The authors show recordings of cardiac ion currents as well as action potential recordings in readily available stem cell–derived cardiomyocytes. Besides monitoring inhibitory effects of reference compounds on typical cardiac ion currents, the authors revealed for the first time drug-induced modulation of cardiac action potentials in an automated patch clamp system. The combination of an in vitro cardiac cell model with higher throughput patch clamp screening technology allows for a cost-effective cardiotoxicity prediction in a physiologically relevant cell system.
Andere Autor:innenVeröffentlichung anzeigen -
All publications
-
Veröffentlichung anzeigenFind all publications on ResearchGate.
https://www.researchgate.net/profile/Michael_George14
Sprachen
-
German
-
-
Swedish
-
-
English
-