When adding Zena Head units (Multiple heads with 1 external compressor) I could only get these to add if I provided the V4 IP Address and the key as provided on a stick on label on the unit and left the password field empty. Any attempt to add with just the IP Addr resulted in a failure message in the log:-
(Time Stamp) ERROR (MainThread) [pydaikin.daikin_base] Exception in TaskGroup: Cannot connect to host 192.168.0.234:80 ssl:default [Connect call failed ('192.168.0.234', 80)]
Documentation as is doesn't identify this and the pop up window in the setup for these suggests that only a different module requires key and password where as mine needed key only and leave password blank.
I'm in AU if this matters as I note that not all regions get the same Daikin gear operating the same way
Regards